 MPW2100 Series
20W, Wide Input Range, Single & Dual Output DC/DC Converters
Key Features
Efficiency up to 87% 1500VDC Isolation MTBF > 1,000,000 Hours Complies with EN55022 Class A Six-Sided Shielding Remote On/Off Control Over Voltage Protection Output Trim Low Profile: 0.37" (9.3mm) Soft Start
OVP
Protection Remote on/off
4:1
Wide Range
1500 VDC
I/O Isolation
EMI
EN55022 Low Profile
Minmax's MPW2100-Series power modules are low-profile dc-dc converters that operate over input voltage ranges of 10-40VDC and 18-75VDC which provide precisely regulated output voltages of 3.3V, 5V, 12V, 15V, {12V and {15VDC, specially addressing data communication equipments, mobile battery driven equipments, distributed power systems, telecommunication equipments, mixed analog/digital subsystems, process/machine control equipments, computer peripheral systems and industrial robot systems. Packing up to 20W of power into a 2x1.6x0.37inch package, with efficiencies as high as 87%, the MPW2100 includes continuous short circuit protection, overvoltage protection, output trim function, remote on/off, six-sided shielded case and EN55022 Class A conducted noise compliance minimize design-in time, cost and eliminate the need for external filtering.
Absolute Maximum Ratings
Parameter Input Surge Voltage ( 1000 mS ) Internal Power Dissipation 24VDC Input Models 48VDC Input Models Min. -0.7 -0.7 ----Max. 50 100 260 4500 Unit VDC VDC ] mW
Environmental Specifications
Parameter Operating Temperature Operating Temperature Storage Temperature Humidity Cooling RFI Conducted EMI Conditions Ambient Case Min. -40 -40 -50 --Max. +65 +105 +125 95 Unit ] ] ] %
Lead Temperature (1.5mm from case for 10 Sec.)
Exceeding the absolute maximum ratings of the unit could cause damage. These are not continuous operating ratings.
Free-Air Convection Six-Sided Shielded, Metal Case EN55022 Class A
1
MINMAX
REV:4 2009/02/27
MPW2100 Series
Model Selection Guide
Model Number Input Voltage Output Voltage Output Current Input Current Reflected Ripple Current mA (Typ.) Over Voltage Protection VDC 3.9 6.8 15 18 {15 {18 3.9 6.8 15 18 {15 {18 Efficiency
VDC MPW2131 MPW2132 MPW2133 MPW2134 MPW2136 MPW2137 MPW2141 MPW2142 MPW2143 MPW2144 MPW2146 MPW2147
24 ( 10 ~ 40 )
48 ( 18 ~ 75 )
VDC 3.3 5 12 15 {12 {15 3.3 5 12 15 {12 {15
Max. mA 4000 4000 1670 1340 {835 {670 4000 4000 1670 1340 {835 {670
Min. mA 240 240 100 80 {50 {40 240 240 100 80 {50 {40
@Max. Load mA (Typ.) 688 1004 960 962 960 962 344 502 480 481 480 481
@No Load mA (Typ.)
20
50
10
25
@Max. Load % (Typ.) 80 83 87 87 87 87 80 83 87 87 87 87
Capacitive Load
Models by Vout Maximum Capacitive Load # For each output 3.3V 5000 5V 5000 12V 500 15V 500 {12V # 330 {15V # 330 Unit uF
Input Fuse Selection Guide
24V Input Models 5000mA Slow - Blow Type 48V Input Models 3000mA Slow - Blow Type
Input Specifications
Parameter Start Voltage Under Voltage Shutdown Reverse Polarity Input Current Short Circuit Input Power Input Filter All Models Model 24V Input Models 48V Input Models 24V Input Models 48V Input Models Min. 9.4 17 9 16 ----Typ. 9.7 17.5 9.3 16.5 ----Pi Filter Max. 10 18 9.5 17 2 4500 A mW VDC Unit
REV:4 2009/02/27
MINMAX
2
MPW2100 Series
Output Specifications
Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20MHz) Ripple & Noise (20MHz) Ripple & Noise (20MHz) Over Power Protection Transient Recovery Time Transient Response Deviation Temperature Coefficient Output Short Circuit 25% Load Step Change Over Line, Load & Temp. Dual Output, Balanced Loads Vin=Min. to Max. Io=50% to 100% Conditions Min. --------------120 ------Continuous Typ. {0.5 {0.5 {0.2 {0.3 55 ------150 {2 {0.01 Max. {1.0 {2.0 {0.5 {1.0 80 100 10 220 300 {4 {0.02 Unit % % % % mV P-P mV P-P mV rms % uS % %/]
General Specifications
Parameter Isolation Voltage Rated Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency MTBF MIL-HDBK-217F @ 25], Ground Benign Conditions 60 Seconds Flash Tested for 1 Second 500VDC 100KHz,1V Min. 1500 1650 1000 --290 1000 Typ. ------1200 330 --Max. ------1500 360 --Unit VDC VDC M[ pF KHz K Hours
Remote On/Off Control
Parameter Supply On Supply Off Device Standby Input Current Control Input Current ( on ) Control Input Current ( off ) Control Common Vin -RC = 5.0V Vin -RC = 0V Conditions Min. 2.5 to 50VDC or Open Circuit -1 --------2 ----1 5 5 -100 Typ. Max. Unit VDC VDC mA uA uA
Referenced to Negative Input
Output Voltage Trim
Parameter Trim Up / Down Range Conditions % of nominal output voltage Min. {9.0 Typ. {10.0 Max. {11.0 Unit %
Notes1:
1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice.
3
MINMAX
REV:4 2009/02/27
MPW2100 Series
Block Diagram
Single Output Dual Output
+Vin
LC Filter
+Vo
+Vin
LC Filter
+Vo Com.
-Vo OVP -Vin On/Off PWM Isolation Ref.Amp Trim OVP -Vin On/Off PWM Isolation Ref.Amp OVP OVP
-Vo
Trim
Input Voltage Transient Rating
150 140 130 120 110 100 Vin ( VDC ) 90 80 70 60 50 40 30 20 10 0 10uS 100uS 1mS 10mS 100mS 24VDC Input Models 48VDC Input Models
REV:4 2009/02/27
MINMAX
4
MPW2100 Series
100 90 Efficiency (%)
100 90 Efficiency (%)
Low Nom Input Voltage (V) High
80 70 60 50
80 70 60 50
Low
Nom Input Voltage (V)
High
Efficiency vs Input Voltage ( Single Output )
Efficiency vs Input Voltage ( Dual Output )
100 90 Efficiency (%)
100 90 Efficiency (%) 80 70 60 50 40
10 20 40 60 80 100
80 70 60 50 40 30 Load Current (%)
30
10
20
40
60
80
100
Load Current (%)
Efficiency vs Output Load ( Single Output )
Efficiency vs Output Load ( Dual Output )
100 100LFM 80 Output Power (%) Natural convection 200LFM 400LFM
60
40
20 0 -40
~ 50 60 70 80 90 100 110
Ambient Temperature ]
Derating Curve
5
MINMAX
REV:4 2009/02/27
MPW2100 Series
Test Configurations
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to simulate source impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope + Battery + Lin Current Probe +Vin +Out Load
Output Voltage Trim
Output voltage trim allows the user to increase or decrease the output voltage set point of a module. The output voltage can be adjusted by placing an external resistor (Radj) between the Trim and +Vout or -Vout terminals. By adjusting Radj, the output voltage can be change by {10% of the nominal output voltage.
+Vin -Vin Enable +Out Trim Down -Out Trim Up Trim 10K Trim Up/Down
DC / DC Converter -Vin -Out
Cin
Peak-to-Peak Output Noise Measurement Test
Use a Cout 1.0uF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter.
+Vin Single Output DC / DC Converter -Vin -Out +Out Copper Strip Cout Copper Strip Scope Resistive Load
A 10K, 1 or 10 Turn trimpot is usually specified for continuous trimming. Trim pin may be safely left floating if it is not used. Connecting the external resistor (Radj-up) between the Trim and -Vout pins increases the output voltage to set the point as defined in the following equation:
Radj-up =
(33*Vout)- (30*Vadj) Vadj - Vout
Connecting the external resistor (Radj-down) between the Trim and +Vout pins decreases the output voltage set point as defined in the following equation:
Radj-down =
(36.667*Vadj) - (33*Vout) Vout-Vadj
Vout : Nominal Output Voltage
+Vin Dual Output DC / DC Converter -Vin +Out Com. -Out Copper Strip Cout Copper Strip Cout Copper Strip Scope Scope Resistive Load
Vadj : Adjusted Output Voltage Units : VDC/ K[
Overcurrent Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range.
Design & Feature Considerations
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is -1V to 1.0V. A logic high is 2.5V to 100V. The maximum sink current at the on/off terminal (Pin 4) during a logic low is -100 uA. The maximum allowable leakage current of a switch connected to the on/off terminal (Pin 4) at logic hight (2.5V to 100V) is 5uA. REV:3 2009/01/22
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data.
MINMAX
6
MPW2100 Series
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0[ at 100 KHz) capacitor of a 33uF for the 24V input devices and a 10uF for the 48V devices.
+ DC Power Source + Cin -Vin -Out +Vin DC / DC Converter +Out Load
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 105 C. The derating curves are determined from measurements obtained in an experimental apparatus.
Position of air velocity probe and thermocouple 15mm / 0.6in
50mm / 2in
Air Flow
DUT
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 4.7uF capacitors at the output.
+ DC Power Source -Vin +Vin Single Output DC / DC Converter -Out +Out
Cout
Load
+ DC Power Source -
+Vin
+Out Dual Output Com. DC / DC Converter Cout Cout Load Load
-Vin
-Out
Maximum Capacitive Load
The MPW2100 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. For optimum performance we recommend 330uF maximum capacitive load for dual outputs, 500uF capacitive load for 12V & 15V outputs and 5000uF capacitive load for 3.3V & 5V outputs. The maximum capacitance can be found in the data sheet.
7
MINMAX
REV:4 2009/02/27
MPW2100 Series
Mechanical Dimensions
40.6 [1.60]
10.20 [0.402] 10.20 [0.402] 10.20 [0.402]
Physical Characteristics
5.0 [0.20] 6.0 [0.24]
9.3 { 0.4 [0.37]
Case Size Case Material
:
50.8*40.6*9.3 mm 2.0*1.6*0.37 inches
: Metal With Non-Conductive Baseplate : 48g : UL94V-0
5
6
7
8
Weight Flammability
45.70 [1.801]
Bottom
50.8 [2.00]
Side
1
2
4
5.10 [0.201]
7.6 [0.30]
2.5 [0.10]
1.00[
0.039]
Heat-sink Material : Aluminum Finish
23.0[0.91]
: Anodic treatment (black) : 2g
Weight
16.3[0.64] max.
The advantages of adding a heatsink are: 1.To help heat dissipation and increase the stability and reliability of DC/DC converters at high operating temperature atmosphere. 2.To upgrade the operating temperature of DC/DC converters, please refer to Derating Curve.
55.32[2.18] max.
Heat-Sink Thermal pad Clamp Converter
Tolerance
Millimeters X.X{0.25 X.XX{0.13
Inches X.XX{0.01 X.XXX{0.005 {0.002
Pin Notes2:
{0.05
1. To order the converter with Heatsink, please add a suffix H (e.g. MPW2142H).
Pin Connections
Pin 1 2 4 5 6 7 8 Single Output +Vin -Vin Remote On/Off No Pin +Vout -Vout Trim Dual Output +Vin -Vin Remote On/Off +Vout Common -Vout Trim
REV:4 2009/02/27
MINMAX
8


▲Up To Search▲   

 
Price & Availability of MPW2131

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X